This video walks through the touchscreen interface of the THEO MA1 ULTRA handheld laser welder: the precautions screen, basic mode, expert mode, the details tab, wire feeder settings, tacking mode, pulse settings, alarms, saved parameters and the system pages. It points out what is different from the MA1-35, MA1-45 and MA1-65.
Basic mode
When you switch on main power, the precautions page appears. Press Agree to reach basic mode:
- Material selection.
- Grosime: one dial with arrows on each side instead of separate tabs. Its range depends on how reflective the material is, so aluminum tops out at a lower thickness than steel.
- Welding method: butt, inner fillet and outer fillet. A few redundant methods were removed.
- Wire diameter: new on the ULTRA. Together with the material and thickness, it adjusts the wobble width and frequency slightly.
- Funcția wire feed quick toggle, and the fish scale quick toggle for the default pulse settings.
- Laser enable, with the same warning: by now your PPE should be on.
Expert mode
- Frequency: the default across most applications is 50 instead of 60 on the MA1-35, MA1-45 and MA1-65. You can slow it down or go above 300.
- Putere: set in percent as before, but of 2000 W, so the minimum is 200 W.
- Wobble width: the default is slightly lower, 2.5 mm, to get even more penetration out of the 2000 W.
- The wire feed quick toggle and the same gas purge as on the other models.
Details tab: new names, same functions
The details tab works as on the MA1-35, MA1-45 and MA1-65, with new names:
- Gas on and gas off delay are now pre-flow și post-flow.
- Light off delay is now burn back.
- Ramp up and ramp down are now up slope și down slope, with a default of 200 ms.
Wire feeder settings
The wire feeder settings are about the same, still without a feed delay by default. A good starting point is a feed delay of 250 ms, so the wire starts after the 200 ms up slope. In the video the up slope is also set to 250 ms, so a feed delay of about 280 ms would fit better.
Tacking mode and pulse settings
Tacking mode works exactly as before, with new names. Spot time is the laser-on time (before: shooting time). Spot interval is the time between spots (before: shooting interval). Use it for stitch welding and autogenous tacking.
The pulse settings match the earlier models. Laser frequency is the number of times per second the laser is pulsed, and duty cycle is still there. If you use a pulsed light mode, set the wire feed to match it: then you can adjust the pulse duration of the feed and the texture smoothness for a more even, micro-TIG-like bead.
Keep in mind that the ULTRA is still a CW machine, built to run in continuous wave. For the most consistent results, stay in CW.
Status and alarms
The status and alarm pages are the same on the MA1-45, MA1-65 and ULTRA, and many MA1-35 units share them. An alarm, such as gas or interlock, shows on the screen, flashes indicator lights on the torch and on the machine, and sounds several audio alarms. If you see an error in the middle or right column, get support in the THEO Toolbox app.
Save and load parameters
- When a set of parameters works well for you, press Save As and give it a name you will remember.
- To type numbers and special characters, use the up arrow above the space key on the left of the keyboard.
- Memories shows the built-in factory presets on the left and your custom presets, with 32 empty slots.
- From that page you can adjust the light mode wire feed settings, turn the wire feed on or off, quick save changes with Save, and load a preset with Load Settings.
System information and configuration
System information lists the serial numbers and firmware versions, including the torch firmware and the wire feeder version. The authorization code key is where you enter your authorization code and any extra feature keys, for example the key that enables cobot mode.
Below it, Configuration asks for a login code and leads to the factory threshold settings. Only authorized personnel should open it, such as THEO service staff and resellers trained by THEO. End users should stay out: changing thresholds too far can damage the unit.
More THEO MA1 Series tutorials
Questions about your machine? Get support in the THEO Toolbox app for iOS and Android.